MARTINDALE MM84 Betriebsanweisung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
E-Ze Check
Xtra Non-Trip Earth Loop Impedance
16th Edition / BS 7671 / Part P
EZ150
Nominal supply: 230V, 50 Hz
Earth loop impedance span:
0-1.7Ω, 1.7 to 5Ω, 5 to 10Ω, 10 to
100Ω, 100 to 200Ω, 200 to 500Ω
Earth loop threshold accuracy:
±(10% + 0.3Ω)
Voltage low indication: <195V
Voltage high indication: >270V
Open earth indication: >500Ω
Power consumption: <1.6 W
Overvoltage: CAT II /300 V
Dimensions: 65 x 65 x 50mm
Weight: 64g approx.
Like all other indicators this unit
cannot detect common earth and
neutral or earth neutral reversal.
This unit is an indicator and is not
designed to give readings for
completing certificates.
A unique new earth loop indicator with voltage and
wiring checks.
Conventional indicators have the weakness that they
only show if the earth is connected, they don’t indicate
how safe it is.
Martindale’s new T-Safe™ Technology gives safe,
earth loop impedance checking within carefully
selected bands, without tripping the RCDs.
Non-trip earth loop check
Voltage test
Socket test
T-Safe™ technology
Identifies faults other checkers can’t
For use in 13A mains socket only
12
E-Ze Check
Xtra Professional Kit
EZ650
EZ150 Specification: see above
TL88 Specification: see page 63
Includes: mains lead (EX332 13A)
& 3 way fused leads (TL88)
This unit is an indicator and is not
designed to give readings for
completing certificates.
“low cost earth loop
indication of sockets
and on lighting
and other circuits”
The E-Ze Check™ Pro Kit is supplied in a custom
designed carry case for convenience. It has an IEC
socket with an interchangeable 3 pin adaptor and TL88
3 way fused leads with croc clips, allowing testing at
light fittings, distribution boards and terminals.
It uses the same technology as the EZ150 above, but
in a multipurpose housing.
This housing allows connection either to an adaptor
with a mains plug, or one with 3 way flying leads for
use on lighting circuits or on bare wires.
This unit is an indication and is not designed to give
readings for completing certificates.
are your
sockets
really safe?
MAREZ150 non-trip earth loop impedance indicator £55.20
MAREZ650 non-trip earth loop impedance indicator kit £99.60
G
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare