500V Analogue Insulation Tester
16th Edition / BS 7671 / Part P
IN1001
Insulation Test: 500V
Insulation range: 0-100MΩ (500V)
Voltage V~
Range: 0-500V AC
Accuracy: ±3% of full scale
Input Impedance: 250KΩ nominal
Continuity (Ω)
Range: 0-2Ω
Test Voltage: 4V DC min
Short Circuit Current: 200mA min
Accuracy: ±1.6mm of scale arc
Buzzer
Range: operates below 1Ω
On all ranges:
buzzer operates after 4 min if tester
is switched on
Current Consumption: 240mA
nominal
Resistance
Range: 0-200Ω
Test Voltage: 4V DC min
Short Circuit Current: 20mA min
Accuracy: ±1.6mm of scale arc
Complies with: BS EN 61557 &
BS 7671
Housing: polycarbonate/ABS
Dimensions: 190 x 90 x 54mm
Weight: 0.5kg approx
Includes: batteries, manual, carry
case & test leads (TL47)
This analogue insulation and continuity tester is
designed to carry out testing in accordance with
national and international standards.
It has a ‘push to operate’ and ‘turn to latch’ test button
on the insulation ranges as standard.
This instrument will indicate the presence of voltage if
connected to a live supply.
It would be suitable for users who prefer the simplicity
of analogue indication.
Single range tester
This supercedes the Metrohm 16A500 and is widely
specified by utilities and major contractors
MARIN1001 insulation tester £248.50
TC2A calibration £27.00
MARTL57 optional fused test leads £32.40
8
250V/500V/1000V Analogue Insulation Tester IN1003
Insulation Test: 250/500/1000V
Insulation range:
0-50MΩ (250V)
0-100MΩ (500V)
0-200MΩ (1000V)
Voltage V~
Range: 0-500V AC
Accuracy: ±3% of full scale
Input Impedance: 250KΩ nominal
Continuity (Ω)
Range: 0-2Ω
Test Voltage: 4V DC min
Short Circuit Current: 200mA min
Accuracy: ±1.6mm of scale arc
Buzzer
Range: operates below 1Ω
On all ranges: buzzer operates
after 4 min if tester is switched on.
Current Consumption: 240mA
nominal
Resistance: 0-200Ω
Test Voltage: 4V DC min
Short Circuit Current: 20mA min
Accuracy: ±1.6mm of scale arc
Housing: polycarbonate/ABS
Dimensions: 190 x 90 x 54mm
Weight: 0.5kg approx
Includes: batteries, manual, carry
case & test leads (TL47)
In addition to the above, this instrument measures at 3
voltages - 250V, 500V and 1000V.
It would be suitable for users who prefer the simplicity
of analogue indication while retaining the accuracy
required for Part P, BS7671 and 16th Edition testing.
Three range tester
This supercedes the Metrohm 16A251
MARIN1003 insulation tester £295.00
TC2A calibration £27.00
MARTL57 optional fused test leads £32.40
N