1
* Current on 10 A range applied for 30 seconds maximum
AC coupled true rms specifi ed from 5% to 100% of range.
Crest factor: d 3.
Overload protection:
0.5A/600V fast blow ceramic fuse on 200μA to 200mA ranges
20A/600V fast blow ceramic fuse on 20A range
Resistance
Range Resolution Accuracy
200: 0.01: ± (0.25% of rdg + 10 dgts)
2k: 0.0001k:
± (0.15% of rdg + 3 dgts)20k: 0.001k:
200k: 0.01k:
2M: 0.0001M: ± (0.25% of rdg + 10 dgts)
20M: 0.001M: ± (1.0% of rdg + 10 dgts)
Open circuit voltage: 3.3V DC approx.
Overload protection: 500V DC or AC rms.
Frequency
Range Resolution Accuracy
2 kHz 0.1 Hz
± (0.5 % of rdg + 3 dgts)
20 kHz 1 Hz
200 kHz 10 Hz
Input sensitivity: 50mV rms minimum for sine wave
400mV rms minimum at >30% and <70% duty cycle
Minimum input: 22Hz range > 2Hz, 220Hz range > 20Hz
Minimum pulse width: >2μs at >10Hz
Overload protection: 500V DC or AC rms
Speci cation
MM84
True RMS Digital Multimeter
MM84 instructions.indd 2 03/07/2012 15:48:29
Speci cation
MM84
True RMS Digital Multimeter
Duty Cycle
Range Frequency
Range
Resolution Pulse
Width
Accuracy (5V Logic)
0% to 90% 20Hz to 20kHz 0.1 % >10 us ±(2.0% rdg + 10 dgts)
Overload protection: 500V DC or AC rms
Continuity
Audible indication: <150:
Response time: Approx 500ms
Open circuit voltage: 3.3V DC approx
Overload protection: 500V DC or AC rms
Diode Test
Range Resolution Test
Current
Open Circuit
Voltage
Accuracy
2V 0.1mV 1.0 mA 3.3V DC approx ± (0.5% rdg + 1 dgt)
Overload protection: 500V DC or AC rms
Logic Test
Thresholds Pulse Rise
Time (Max)
Pulse
Repetition
Rate (Max)
Pulse Width
(Min)
Logic 1 (Hi) Logic 0 (Lo)
2.8V ± 0.8V 0.8V ± 0.5V 10μs 1 Mpps 25ns
Duty cycle: > 20% and < 80%
Frequency response: 20 MHz
Overload protection: 500V DC or AC rms
MM84 instructions.indd 5 03/07/2012 15:48:29
GENERAL SPECIFICATIONS
Display: 4½ digit liquid crystal display with a maximum reading of 19999
Analog bargraph: 22 segments with measurement 20 times per second
Polarity: Automatic, positive implied, negative polarity indication
Overrange: Most signifi cant digit displays “1”
Low battery indication:
symbol is displayed when the battery voltage drops below the operating level
Measurement rate: 2.5 times per second, nominal
Auto power off: After approx 45 minutes
Operating environment: 0°C to 50°C at < 70% RH
Storage temperature: -20°C to 60°C at < 80% RH
Altitude: Up to 2000m
Power: Single standard 9 volt battery, NEDA 1604, JIS006P, IEC 6F22
Battery Life: 300 hours typical with carbon-zinc
Dimensions: 189 (H) x 87 (W) x 37 mm (D)
Weight: 330g approx. including battery
Includes: TL16 test leads, holster, 9V battery (installed) and instructions.
SAFETY:
Conforms to BS EN61010-1, CAT II 1000V DC, 750V AC
Class II Double Insulation
Pollution Degree: 2
TL16 test leads conform to BS EN61010-031, CAT III 1000V, CAT IV 600V, 10A
EMC: Conforms to BS EN 61326
Speci cation
MM84
True RMS Digital Multimeter
MM84 instructions.indd 4 03/07/2012 15:48:29
Check out what else you can get from Martindale:
Martindale Electric Company Limited
Metrohm House, Penfold Trading Estate, Imperial Way, Watford WD24 4YY, UK
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
E-mail: sales@martindale-electric.co.uk
Website: www.martindale-electric.co.uk
© 2012 Martindale Electric Company Ltd.
Registered in England No. 3387451. E. & O.E. Document Rev1 LITMM84
• 17th Edition Testers
• Accessories
• Calibration Equipment
• Continuity Testers
• Electricians’ Kits
• Environmental Products
• Full Calibration & Repair Service
• Fuse Finders
• Digital Clamp Meters
• Digital Multimeters
• Labels
• Microwave Leakage Detectors
• Motor Maintenance Equipment
• Multifunction Testers
• Non-trip Loop Testers
• Pat Testers & Accessories
• Phase Rotation Testers
• Proving Units
• Socket Testers
• Thermometers & Probes
• Test Leads
• Voltage Indicators
• Specialist Metrohm Testers (4 & 5kV)
• Specialist Drummond Testers
MM84 instructions.indd 1 03/07/2012 15:48:24
Kommentare zu diesen Handbüchern